AC Electricity Cost Calculator
Use the yearly units on the AC's star label, or its tonnage and ISEER, to see what an hour, a month and a whole summer of cooling costs, and how much a more efficient model would save.
A planning estimate. Real use depends on the room, the weather, the set temperature and how often the door opens.
A 1.5-ton AC with an ISEER of 4.5, running eight hours a night at an average 60% load, uses about 0.70 units an hour. Over a 30-day month that is 168.8 units, and at ₹7 a unit, ₹1,182. Six months of that is just over ₹7,000 for one room.
Which of the three inputs to use
If you have the star label, start with the yearly units printed on it. That figure comes from a standard test that weights performance across the outdoor temperatures India actually sees (24°C to 43°C) and assumes about 1,600 hours of cooling a year. Dividing by 1,600 gives an average units-per-hour that already allows for the compressor slowing down or switching off. A label showing 1,000 units a year works out to 0.625 units an hour.
The tons-and-ISEER option is for comparing models in a shop or online, where the ISEER is listed but the yearly figure may not be. It uses the fact that one ton of cooling is 3.517 kW of heat removed, and ISEER tells you how many units of heat the AC moves for every unit of electricity it uses:
Rated input power from the specification sheet is the draw at full output on a hot day. Multiply by the average load for a realistic figure. A 1,500 W rating at 70% load is 1.05 units an hour, which is why a rough rule of "1.5 ton = 1.5 units an hour" usually overstates the bill for a modern AC.
The average load setting is a guess, so test it
An AC rarely runs flat out for hours. On a mild evening with the room already cool, it might average well under half its capacity; in a west-facing top-floor bedroom in May, it may run close to full. The 60% default is a middle value, not a measurement. Move the slider and the monthly figure moves in step:
| Average load | Units an hour | Units a month | Cost a month |
|---|---|---|---|
| 40% | 0.469 | 112.5 | ₹788 |
| 60% | 0.703 | 168.8 | ₹1,182 |
| 80% | 0.938 | 225.1 | ₹1,576 |
| 100% | 1.172 | 281.4 | ₹1,970 |
1.5 ton, ISEER 4.5, 8 hours a day, 30 days, ₹7 a unit.
If you already have a month of bills with and without the AC, the difference in units is the best check. Adjust the load until the calculator matches it, then use that setting to plan the rest of the summer.
What a better ISEER is worth
Keep everything else the same and change only the ISEER from 4.5 to 5.5. Units an hour drop from 0.703 to 0.576, the monthly bill falls from ₹1,182 to ₹967, and the six-month season costs ₹1,289 less. If the more efficient model costs ₹8,000 more, it takes a little over six summers to earn that back at this level of use. Run the AC twelve hours a day and the payback shortens; use it only on the worst nights of May and it may never come.
Compare ISEER numbers rather than stars. BEE has raised the bar for each star level several times since the programme began (in 2023 the government reported that the efficiency of a 5-star split AC had improved by 61% under the programme), so a 5-star AC from a few years ago and a 5-star AC on sale today are not the same.
Inverter and fixed-speed ACs
A fixed-speed (non-inverter) AC has a compressor that is either on at full power or off. It cools the room past the set point, switches off, lets the room warm up, and starts again. Each start draws a surge of current and the room temperature swings by a degree or two. An inverter AC varies the compressor's speed, so once the room is cool it keeps running slowly instead of stopping and starting. Over a long night it usually uses fewer units for the same comfort, and the room stays at a steadier temperature.
Both types carry the same BEE star label rated by ISEER, so you can compare them directly. The label shows the star rating, the ISEER, the cooling capacity and the yearly units. If you are deciding whether to buy at all, put the AC into the appliance cost calculator alongside your other appliances to see its share of the bill, or look at rooftop solar if summer bills are the main problem.
Frequently asked questions
Does a higher temperature setting really lower the bill?
Yes. At 26°C the AC has less heat to pull out of the room than at 20°C, so the compressor runs slower or stops more often. That is why the default setting on new room ACs has been 24°C since 1 January 2020 under BEE's labelling rules. In the calculator, a warmer setting shows up as a lower average load.
Is a 2-ton AC twice as expensive to run as a 1-ton AC?
Only if both work equally hard. Capacity sets the ceiling, not the actual draw. A 2-ton AC in a room that needs 1 ton will reach the set temperature quickly and then idle, while an undersized AC in a hot top-floor room may run flat out for hours. Pick the size for the room, then compare models by ISEER.
My bill rose by more than this calculator shows. Why?
The AC's units sit on top of everything else you use, so they fall into your most expensive slab. Put your top slab rate, plus duty, in the rate box. The electricity bill calculator shows the rate your next unit is charged at.